Applicable standards | IEC60947-5-1/EN60947-5-1/GB14048.5-2017 |
---|---|
Degree of protection | IP67 (EN60947 - 5- 1, Except for the key operating hole ) |
Service life | More than 1 million mechanical times / more than 150,000 times electrical |
Tensile strength when locked | 1300 N |
Rated insulation voltage | 300V |
Rated impulse with stand voltage | 2.5Kv |
conventional free air thermal current | 10A |
Utilization category | AC-15/DC-13 |
Rated operating voltage | AC240V/DC30V/DC250V |
Rated operating current | 3A/2.3A/0.27A |
Rated conditional short-circuit current | 1000A |
Direct opening force | ≥60 N |
Direct opening travel | ≥10mm |
Operating frequency | ≤20 times/minute |
Ambient temperature | -20°C~60°C (no ice) |
Ambient humidity | 85% RH below |